problem: the user cannot see all the values on his prompts, but a brand new user with the same rights can. report written in BO FC 5.1
symtoms: list of prompts cannot be refreshed when the user opens BO FC 5.1 report on webi 6.5
the object is a filter
filter name: Annee/Mois ?
where: @Select(Periode de connexion\Annee/Mois) IN @Prompt('Choisissez une ou plusieurs periode','A','Periode de connexion\Annee/Mois',MULTI,FREE)
reason: bug
solution: create a new user, copy the personal reports of the old user to this user and delete the old user.
lundi 17 décembre 2007
vendredi 7 décembre 2007
Locked General Supervisor
This saved my life today.
If you don't have a second general supervisor, you could try the following SQL run against the security domain database:
Code:
Update OBJ_M_ACTOR Set M_ACTOR_C_PASSWORD = NULL Where M_ACTOR_C_NAME =;
This will set the password for the general supervisor to null, and therefore the next time you login, you will not need to enter a password. It is recommended that a password is given asap via the supervisor module. You will also have to set the status of the user login, otherwise even with a null password BusObj will not let you log in. The status column is in OBJ_M_ACTOR and is called M_ACTOR_N_STATUS. If you set this flag to 1 along with setting the password to null then you should be okay. If this still doesn't work, make sure you have commited the database update
If you don't have a second general supervisor, you could try the following SQL run against the security domain database:
Code:
Update OBJ_M_ACTOR Set M_ACTOR_C_PASSWORD = NULL Where M_ACTOR_C_NAME =
This will set the password for the general supervisor to null, and therefore the next time you login, you will not need to enter a password. It is recommended that a password is given asap via the supervisor module. You will also have to set the status of the user login, otherwise even with a null password BusObj will not let you log in. The status column is in OBJ_M_ACTOR and is called M_ACTOR_N_STATUS. If you set this flag to 1 along with setting the password to null then you should be okay. If this still doesn't work, make sure you have commited the database update
lundi 23 juillet 2007
Dw com BO
Assunto técnico em informática de Datawarehouse com Business Objects
Caso não lhe interesse, visite tapioca do bill.
Caso não lhe interesse, visite tapioca do bill.
Inscription à :
Commentaires (Atom)
